Search results for "Erector spinae"

showing 8 items of 8 documents

Sarcopenia as prognostic factor for survival after orthotopic liver transplantation

2020

Background and aim Body composition has emerged as a prognostic factor for end-stage liver disease. We therefore investigated muscle mass, body fat and other clinical-pathological variables as predictors of posttransplant survival. Methods A total of 368 patients, who underwent orthotopic liver transplantation (OLT) at our institution, were assessed prior to OLT and followed for a median of 9.0 years (range 2.0-10.0 years) after OLT. Psoas, erector spinae and the combined paraspinal muscle area, as well as the corresponding indices normalized by body-height squared, were quantified by a lumbar (L3) cross-sectional computed tomography. In addition, absolute body fat and bone density were est…

AdultMaleSarcopeniamedicine.medical_specialtyBone densityUrologyEnd Stage Liver Disease03 medical and health sciencesLiver disease0302 clinical medicineLumbarErector spinae musclesHumansMedicineRetrospective StudiesAnatomy Cross-SectionalHepatologybusiness.industryHazard ratioGastroenterologyHepatitis CMiddle AgedPrognosismedicine.diseaseConfidence intervalLiver Transplantation030220 oncology & carcinogenesisSarcopeniaBody CompositionFemale030211 gastroenterology & hepatologyTomography X-Ray ComputedbusinessEuropean Journal of Gastroenterology & Hepatology
researchProduct

Effect of different ergonomic supports on muscle activity of dentists during posterior composite restoration

2019

BackgroundThe aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks.MethodsA one-way repeated measures study (ANOVA) was conducted on a group of 36 dentists. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. Intraclass correlation coefficients (ICCs) and the absolute standard error of measurement (SEM) were used to establish the reliability o…

Anatomy and PhysiologyIntraclass correlationDentistslcsh:MedicineMagnificationElectromyographyMusculoskeletal disordersGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineLumbarErector spinae musclesMedicine0501 psychology and cognitive sciencesMuscle activity050107 human factorsOrthodonticsmedicine.diagnostic_testElectromyographyPhysical therapy modalitiesbusiness.industryGeneral Neurosciencelcsh:R05 social sciencesRepeated measures design030206 dentistryGeneral MedicineKinesiologyOrthopedicsDentistryPublic HealthErgonomicsGeneral Agricultural and Biological SciencesTrunk musclebusinessPeerJ
researchProduct

Determining the optimal maximal and submaximal voluntary contraction tests for normalizing the erector spinae muscles

2019

Background This study aimed to identify which maximum voluntary isometric contraction (MVIC) and sub-MVIC tests produce the highest activation of the erector spinae muscles and the greatest reduction in inter-individual variability, to put them forward as reference normalization maneuvers for future studies. Methods Erector spinae EMG activity was recorded in 38 healthy women during five submaximal and three maximal exercises. Results None of the three MVIC tests generated the maximal activation level in all the participants. The maximal activation level was achieved in 68.4% of cases with the test performed on the roman chair in the horizontal position (96.3 ± 7.3; p < 0.01). Of the fi…

Normalization (statistics)medicine.medical_specialtyAnatomy and Physiologylcsh:MedicineElectromyographyIsometric exerciseGeneral Biochemistry Genetics and Molecular BiologyErector spinae03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationVoluntary contractionRoman chairErector spinae musclesmedicineColumna vertebral - Músculos - Electromiografía.Maximum voluntary isometric contractionmedicine.diagnostic_testbusiness.industryElectromyographyGeneral Neurosciencelcsh:R030229 sport sciencesGeneral MedicineSpine - Muscles - Electromyography.KinesiologyTrunkSub-maximum voluntary isometric contractionNormalizationOrthopedicsElectromyography.Horizontal position representationGeneral Agricultural and Biological SciencesbusinessElectromiografía.030217 neurology & neurosurgery
researchProduct

The quality of recovery after erector spinae plane block in patients undergoing breast surgery: a randomized controlled trial

2022

Abstract Background The erector spinae plane (ESP) block has recently been shown to effectively alleviate postoperative pain and reduce opioid consumption in breast surgery patients. However, data are still limited concerning the quality of recovery in patients following this procedure. Methods This study was a randomized controlled trial (RCT) performed in a university hospital. We randomly allocated patients to one of three groups: ESP, SHAM, and control (CON). Procedures in the ESP and SHAM blocks were performed ipsilaterally with 0.375% ropivacaine or 0.9% saline (0.4 mL/kg). Our primary outcome was the assessment of the patient’s improvement with quality-of-recovery 40 (QoR-40) a day a…

Quality of recoveryPain PostoperativeBreast NeoplasmsNerve BlockBreast surgeryPatient-controlled analgesiaAnalgesics OpioidAnesthesiology and Pain MedicineHumansFemaleVisual analog scaleAnesthetics LocalUltrasonography InterventionalErector spinae plane blockBMC Anesthesiology
researchProduct

Core Muscle Activity, Exercise Preference, and Perceived Exertion during Core Exercise with Elastic Resistance versus Machine

2015

Objectives. To investigate core muscle activity, exercise preferences, and perceived exertion during two selected core exercises performed with elastic resistance versus a conventional training machine.Methods. 17 untrained men aged 26–67 years participated in surface electromyography (EMG) measurements of five core muscles during torso-twists performed from left to right with elastic resistance and in the machine, respectively. The order of the exercises was randomized and each exercise consisted of 3 repetitions performed at a 10 RM load. EMG amplitude was normalized (nEMG) to maximum voluntary isometric contraction (MVC).Results. A higher right erector spinae activity in the elastic exer…

medicine.medical_specialtyCore (anatomy)Article Subjectmedicine.diagnostic_testbusiness.industrylcsh:RLeft external obliquelcsh:MedicinePerceived exertionIsometric exerciseElectromyographyErector spinae musclesPhysical therapyMedicinelcsh:QMuscle activitylcsh:ScienceGeneral Agricultural and Biological SciencesbusinessRight external obliqueResearch ArticleGeneral Environmental ScienceScientifica
researchProduct

The erector spinae plane block: a narrative review

2019

Regional anesthesia and pain management have experienced advances in recent years, especially with the advent of fascial plane blocks. The erector spinae plane block is one of the newest techniques to be described. In the past two years, publications referring to ESP block have increased significantly. The objective of this review is to analyze the articles about ESP block that have been published to date. We performed a search in the main databases and identified 368 articles. After a selection of the relevant articles, 125 studies were found eligible and were included in the review. The ESP block is performed by depositing the local anesthetic in the fascial plane, deeper than the erector…

medicine.medical_specialtymedicine.drug_classParaspinal MusclesPainRegional anesthesiaReview ArticleAnesthesia SpinalPlane (Unicode)lcsh:RD78.3-87.303 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitation030202 anesthesiologyAnesthesia ConductionBlock (telecommunications)Erector spinae musclesMedicineHumansAnesthetics Localbusiness.industryLocal anestheticAnestèsiaChronic pain030208 emergency & critical care medicineNerve BlockESP blockPain managementmedicine.diseaseFascial plane blockAnesthesiology and Pain MedicineRegional anesthesialcsh:AnesthesiologyNarrative reviewChronic PainbusinessErector spinae plane block
researchProduct

Effects of pregnancy on lumbar motion patterns and muscle responses.

2018

The kinematics of the lumbar region and the activation patterns of the erector spinae muscle have been associated with the genesis of low back pain, which is one of the most common complications associated with pregnancy. Despite the high prevalence of pregnancy-related low back pain, the biomechanical adaptations of the lumbar region during pregnancy remain unknown.This study analyzes lumbar spine motion and the activation pattern of the lumbar erector spinae muscle in healthy pregnant women.A case-control study.The study involved 34 nulliparous women (control group) and 34 pregnant women in the third trimester (week 36 ± 1).We recorded the parameters of angular displacement of the lumbar …

musculoskeletal diseasesAdultmedicine.medical_specialtyLigamentous laxityMovementElectromyography03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationLumbarPregnancyErector spinae musclesMedicineEccentricHumansOrthopedics and Sports MedicineRange of Motion ArticularMuscle Skeletal030222 orthopedicsmedicine.diagnostic_testbusiness.industryLumbosacral Regionmedicine.diseaseLow back painTrunkSagittal planeBiomechanical Phenomenamedicine.anatomical_structureSurgeryFemaleNeurology (clinical)medicine.symptombusinessLow Back Pain030217 neurology & neurosurgeryThe spine journal : official journal of the North American Spine Society
researchProduct

AB1197 Changes in Lumbar Spinopelvic Pattern of Movement Influence the Flexion Relaxation of the Erector Spinae

2015

Background In healthy subjects, the erector spinae muscles (ES) exhibits a relaxation of its electrical activity when the trunk is nearby its full flexion. Objectives To find out the influence of exhibiting a lumbar spine or a pelvis dominant pattern of movement during trunk flexion from upright position on the appearance of the myoelectric relaxation of the erector spinae. In healthy subjects, the erector spinae muscles (ES) exhibits a relaxation of its electrical activity when the trunk is nearby its full flexion. Objectives To find out the influence of exhibiting a lumbar spine or a pelvis dominant pattern of movement during trunk flexion from upright position on the appearance of the my…

musculoskeletal diseasesRelaxation (psychology)business.industryImmunologyAnatomyFlexion relaxationmusculoskeletal systemTrunkGeneral Biochemistry Genetics and Molecular BiologySagittal planeLumbarmedicine.anatomical_structureRheumatologyErector spinae musclesImmunology and AllergyMedicineLumbar spinebusinessPelvisAnnals of the Rheumatic Diseases
researchProduct